ACT-1H100HE

• Number of contact groups:

One set of normally open main contacts

• Rated resistive load life: 

100A,270Vd.c., 20,000 times;

• Coil voltage:24-28Vd.c.

• Coil power consumption:≤8W

• Ambientt temperature:-55℃~85℃

• Sinusoidal vibration:

147 m/s2,10 Hz~2000 Hz

Datasheet

ACT-1H200HE

ACT-1H300HE

Datasheet

ACT-1H400HE

• Number of contact groups:

A set of bridge-type normally open main contacts, a set of normally open auxiliary contacts

• Rated resistive load life: 

200A,270Vd.c., 6,000 times;

• Coil voltage:24-28Vd.c.

• Coil power consumption:≤4.1W

• Ambientt temperature:-55℃~85℃

Sinusoidal vibration:

98 m/s2,10 Hz~2000 Hz

Datasheet

• Number of contact groups:

A set of bridge-type normally open main contacts, two sets of changeover auxiliary contacts

• Rated resistive load life: 

400A,270Vd.c., 10,000 times;

• Coil voltage:24-28Vd.c.

• Coil power consumption:≤16.8W

• Ambientt temperature:

-55℃~85℃

• Sinusoidal vibration:

98m/s2,10 Hz~2000 Hz

• Number of contact groups:

A set of bridge-type normally open main contacts, a set of changeover auxiliary contacts

• Rated resistive load life: 

300A,270Vd.c., 12,000 times;

• Coil voltage:24-28Vd.c.

• Coil power consumption:≤14W

• Ambientt temperature:-55℃~85℃

• Sinusoidal vibration:

98 m/s2,10 Hz~2000 Hz

Datasheet

Contactor-High Voltage Direct Current

ACT-1H600HE

• Number of contact groups:

One set of normally open main contacts(can be equipped with auxiliary contacts)

• Rated resistive load life: 

600A,270Vd.c., 6,000 times;

• Coil voltage:24-28Vd.c.

• Coil power consumption:≤14W

• Ambientt temperature:-55℃~85℃

• Sinusoidal vibration:

98 m/s2,10 Hz~2000 Hz

Datasheet

ACT-1H1000HE

Datasheet

ACT-1H1500HE

• Number of contact groups: 

A set of bridge-type normally open main contacts, a set of changeover auxiliary contacts

• Rated resistive load life:

 800A,270Vd.c., 8,000 times;

• Coil voltage:28Vd.c.

• Coil power consumption:≤15W

• Ambientt temperature:-55℃~85℃

• Sinusoidal vibration:

147 m/s2,50 Hz~2000 Hz

Datasheet

• Number of contact groups:

A set of bridge-type normally open main contacts, a set of changeover auxiliary contacts

• Rated resistive load life: 

1500 A,270Vd.c., 3,000 times;

• Coil voltage:28Vd.c.

• Coil power consumption:≤18W

• Ambientt temperature:

-55℃~85℃

• Sinusoidal vibration:

147 m/s2,50 Hz~2000 Hz

• Number of contact groups:

A set of bridge-type normally open main contacts, a set of changeover auxiliary contacts

• Rated resistive load life:

 1000A,270Vd.c., 5,000 times;

• Coil voltage:28Vd.c.

• Coil power consumption:≤18W

• Ambientt temperature:-55℃~85℃

• Sinusoidal vibration:

147 m/s2,50 Hz~2000 Hz

Datasheet

Contactor-High Voltage Direct Current

ACT-1H800HE

ACT-80E

• Number of contact groups:

Three set of normally open main contacts and one set of switching auxiliary contacts

• Rated resistive load life:

 90A,115Vd.c, 30,000 times;

• Coil voltage:28Vd.c.;

• Coil power consumption:≤14W;

• Ambientt temperature:

-55℃~85℃;

Datasheet

Contactor

ACT-83E

• Number of contact groups: 

One set of normally open main contacts and three sets of changeover auxiliary contacts

• Rated resistive load life: 

400A,28Vd.c, 20,000 times;

• Coil voltage:28Vd.c.;

• Coil power consumption:≤6W;

• Ambientt temperature:

-55℃~85℃;

Datasheet